By Julianne Calapa, Sheffield Metals.
No matter what product you work with or your role in the construction process, there are always unique considerations for each product you work with. These are natural as every material acts slightly differently, especially when faced with harsher conditions such as water, wind and other weather events.
Higher exposure to these harsher conditions is what makes paying attention to these considerations especially important with exterior products such as standing seam metal roofing and walls. When these considerations are not properly acknowledged or designed for, the entire enclosure system is vulnerable to failure. In this article, the experts at Sheffield Metals share some of the most crucial considerations when working with standing seam metal.
1 - Geographical location
The geographical location of your project is easily one of the most significant factors to consider when specifying a standing seam roof or wall system. Location matters for several attributes that could affect a metal panel system, including:
One consideration that can make or break a metal roofing system is a building’s proximity to a coastline or saltwater environment. For some reference, it’s recommended that all properties within a certain distance of a coast use an engineered aluminum roof system, as aluminum resists corrosion and rusting from saltwater (unlike steel/Galvalume) for much longer and still comes with both a 40-year paint warranty and a substrate warranty.
We recommend using aluminum panels for these coastline distances:
Luckily, metal is one of the best-performing roofing materials available, so it’s destined to work well in nearly all environments. However, there are still some design considerations to remember. For example, if the property is in a region that gets significant snowfall, you’ll want to ensure the standing seam metal system you specify can be fitted with attachment solutions for snow guards or snow retention systems. Or, if the property is in an area with high sun exposure, you’ll want to specify a metal that has a PVDF paint system, as it performs best and helps to prevent excessive chalking and fading.
Researching climate data is critical in the design stage. Not only will it tell you common weather patterns, but it will indicate any possible extreme weather events that the property could endure. We already discussed the recommended distances from a coastline when it comes to the metal material, but on top of that, you’ll want to specify a roofing profile that is engineered to hold up against extreme weather (such as a double-locked mechanically seamed profile). Or, if your project is in a high wind zone from the threat of hurricanes or tornadoes, it’s critical to specify a profile with a wind uplift engineering report that meets the design criteria for your project. Plus, the option to purchase a weathertight warranty is also a great added value.
Last but not least, some cities, regions and states have distinct building codes based on the location’s specific needs, which means the roof or wall system you design must adhere to these regulations and requirements. This includes such requirements as the Florida Building Code (FBC), Miami-Dade County building codes, Texas Department of Insurance (TDI) and International Code Council Evaluation Services (ICC-ES).
2 - Metal material type
There are five common metals used for architectural metal roofing and wall systems:
Galvalume and aluminum are the two metals specified for the majority of projects, as both materials are highly recyclable (and frequently made from previously recycled materials), durable and long-lasting. We explored the significant difference between these two options above in the fact that aluminum is always recommended on coastal properties, as it does not corrode or rust when in contact with seawater or saltwater. That being said, Galvalume is the most popularly specified metal material, as it’s more rigid than aluminum, costs less and is more readily available.
We could go on for a long time about the individual requirements, inclusions, exclusions and beyond for each metal material. Fortunately, you can learn more about the topic of metal roof material attributes and comparisons here.
3 - Deck substrate
Next on the list of design considerations is the deck substrate that the metal roof or wall is installed on. Decks are separated into two common categories: Open-framing and solid substrate.
Open framing:
Purlin-type system
Solid decking/substrate:
Not all standing seam profiles or metal types can be installed on every decking structure, as some materials have dissimilar properties that could corrode each other, others cannot be installed over specific assemblies and some profile assemblies do not qualify for engineering on particular substrates. It’s also important to note that you will need to check the thickness of the framing/substrate as well. For reference, the typical thickness of purlins is 16 gauge, the typical thickness of metal decking is 22 gauge and the typical thickness of plywood or OSB will typically be around ½” to 5/8”. Ensure you reference the uplift engineering report to ensure that all items in the assembly match the tested assembly.
It’s critical to look closely at the manufacturer’s recommendations and testing requirements for decking substrates, which are typically available where panel profile details are listed.
4 - Pertinent testing requirements
In the architectural metals world, testing and engineering of roofing and wall systems are almost a requirement. No designer or architect wants to specify a panel system that isn’t backed by industry standards, so it’s critical to apply the information you’ve collected about the location, metal material and roof deck. Then, you should ensure it all fits together and was successfully tested by the manufacturer and approved by the standards organizations.
For a little background on the different tests you might encounter during the design phase, let’s go through some of the common basic standards and project-specific tests.
Wind uplift testing standards:
Water penetration testing standard:
ASTM E 1646 – Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
Air infiltration testing standard:
ASTM E1680 – Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems
Hail/impact resistance testing standard:
UL 2218 – Standard for Impact Resistance of Prepared Roof Covering Materials
Fire resistance testing standard (most common):
UL 790 – Standard Test Methods for Fire Tests of Roof Coverings
Check out this article for a detailed breakdown and explanation of these testing requirements. As for more project specific standards and testing, there are a few that we thought were important to highlight.
Water submersion testing standard:
ASTM E2140 – Standard Test Method for Water Penetration of Metal Roof Panel Systems by Static Water Pressure Head (applies to slopes less than 2/12 pitch)
Missile impact testing standard:
ASTM E1886 – Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
Wind-driven rain testing standard:
TAS 100 – Test Procedure for Wind and Wind-Driven Rain Resistance and/or Increased Windspeed Resistance of Soffit Ventilation Strip and Continuous or Intermittent Ventilation System Installed at the Ridge Area
Foot traffic over purlins testing standard:
5 - Areas of concern
The final design consideration to keep in mind when specifying a standing seam metal roof or wall system are the areas of concern, some of which are common in architectural projects. Concerning areas can include:
All of these are areas of concern because they tend to be the areas where the roof can fail in one way or another. This could be a leak at a complex flashing point or water/debris collecting in a dead valley, which can degrade the metal if standing water is present for a long time.
These design elements become a more significant issue when a weathertight warranty is included in the spec. Some conditions may not meet the qualifications for a weathertight warranty and would be excluded if a warranty was to be issued. If any of these areas of concern are a part of the design, but you still want a warranty, our Technical and Architectural Department representatives can work with you to ensure the warranty conditions are met.
Designing and specifying a standing seam metal roof or wall panel system is one of the best ways to ensure a building looks fantastic, all while withstanding exposure and protecting the people and property on the inside. So, once you have identified all the topics above, you can then determine the panel profile options and pick the best one to meet your specific project conditions.
Remember:
For the past decade, Sheffield Metals has been dedicated to creating an architectural program that focuses on growing the businesses of architects, designers and builders. We offer a tested and true selection of engineered profiles for standing seam metal roofs and walls.
Original article source: Sheffield Metals
Learn more about Sheffield Metals International in their Coffee Shop DIrecotry or visit www.sheffieldmetals.com.
The bright future of metal roofing continues to evolve
Read More ...Deciding between felt and synthetic roof underlayment
Read More ...EagleView Launches Cutting Edge SolarReady™ Product; Reshapes Solar Industry
Read More ...
Comments
Leave a Reply
Have an account? Login to leave a comment!
Sign In